- 相關(guān)推薦
循環(huán)流化床煙氣脫硫模擬中試試驗(yàn)研究
摘要: 在東南大學(xué)熱能工程研究所建立的φ600mm,處理煙氣量達(dá)2000m3/h(標(biāo)準(zhǔn)狀態(tài),下同)的循環(huán)流化床煙氣脫硫中試試驗(yàn)臺(tái)上,進(jìn)行了循環(huán)流化床煙氣脫硫的試驗(yàn)研究.分別討論了Ca與S的摩爾比、煙氣流量、入口SO2濃度、反應(yīng)溫度等因素對(duì)脫硫效率影響.試驗(yàn)結(jié)果表明,Ca與S的摩爾比和反應(yīng)溫度的影響最為顯著,煙氣量和SO2入口濃度也有一定的影響,但不十分明顯,說(shuō)明循環(huán)流化床煙氣脫硫工藝對(duì)鍋爐負(fù)荷和燃煤煤種的變化有較好的適應(yīng)性. Abstract: At present, SO2 pollution control of coal combustion is an urgenttask in the field of air pollution control in China. An experimental research was carried on the simulated pilot-scale test facility of Circulating Fluidized Bed for Flue Gas Desulfurization (CFB-FGD) whose diameter is 600mm and nominal flow rate of the flue gas is 2 000 m3/h in Thermal Engineering Research Institute of Southeast University. The Ca/S molar ratio and the reaction temperature have great influence on the efficiency of desulfurization, but the influences of the flow rate and SO2 inlet concentration are not obvious. So the result indicates that CFB-FGD technology is applicable for the variation of the boiler’s load and the coal used. 作 者: 馮斌 李大驥 周志良 吳穎海 楊軍 作者單位: 馮斌,李大驥,吳穎海,楊軍(東南大學(xué)熱能工程研究所, 南京 210096)周志良(江蘇省昆山市環(huán)保局管理處, 昆山 215300)
期 刊: 東南大學(xué)學(xué)報(bào)(自然科學(xué)版) ISTICEIPKU Journal: JOURNAL OF SOUTHEAST UNIVERSITY(NATURAL SCIENCE EDITION) 年,卷(期): 2001, 31(2) 分類(lèi)號(hào): X-505 關(guān)鍵詞: 循環(huán)流化床煙氣脫硫 模擬中試 Ca與S的摩爾比 煙氣流量 入口SO2濃度 反應(yīng)溫度 反應(yīng)濕度【循環(huán)流化床煙氣脫硫模擬中試試驗(yàn)研究】相關(guān)文章: